Cics response code 16
Cics response code 16. Each possible value of EIBRESP relates directly to a specific condition, no Jan 9, 2009 · 33. The CICS user ID or transaction (the CONNX CICS/VSAM server: NXS0 ) is not authorized to perform the requested action against the target file. Learn how to use the RESP option in CICS commands to check the response code and handle exceptions. by mandor » Thu Aug 23, 2012 12:39 pm . Following are the common abend codes with their description which will help you to resolve the issues ? Aug 17, 2005 · Hi Resp code 44 means 'Queue Not Found' ,this occurs only when you are trying to execute follwoing command EXEC CICS READQ QID("qname123") Oct 6, 2008 · JCL & VSAM: Hi, I am trying to write into a KSDS VSAM file and I am getting file status of 16. What is the value in EIBRESP2 as well as EIBRCODE? In order for the user to enter screen data, you must terminate the task and return with a TRANSID, COMMAREA and COMMAREA-LENGTH. 3 The data was created with a data type of BIT. Version. Exceptional Condition is generated when a CICS command encounters an unusual situation. . Operator response. 17. After the execution of an EXEC CICS command, fields EIBRESP and EIBRCODE are set to indicate whether the command executed successfully, or whether a CICS® condition was raised. EXEC CICS INVOKE WEBSERVICE or INVOKE SERVICE results are EIBRESP 16 (INVREQ) EIBRESP2 17 (A remote Web service request did not return a response message). Set return code 16 for the caller. The primary code returned by the RESP option is the general result - either NORMAL, meaning that the command executed successfully, or the name of an exception Note: For commands where EIBRESP and EIBRESP2 are used for interrogating the resulting condition of an executed command, byte 3 of EIBRCODE has the same value as EIBRESP. Jun 15, 2018 · You are running batch jobs using the External CICS Interface (EXCI) application programming interface (API). Additional information for the NOTAUTH (Not Authorized) CICS response. Unbound response from CICS Web Service by Marty19 » Wed Mar 26, 2014 2:14 pm The EXCI call interface is part of the external CICS interface that enables a non-CICS program (a client program) running in z/OS to call a program (a server program) running in a CICS region and to pass and receive data by using a communications area or by using a channel and a set of containers. 0 15. 9 Return area for the EXCI CALL interface. WRITE writes a new record to a file on a local or a remote system. A resource security check failed on the target file. These words will contain the RESP and RESP2 codes. 1 200 OK. For a normal response, this field contains hexadecimal zeros (6 X'00'). I have same program in a program which gets executed couple of programs before this program and the read is happening correctly there and the return codes are 000000. CICS® sets a primary and sometimes a secondary response code when it completes a command, and provides options for you to inspect them. May 9, 2011 · An EIBRESP of 16 in an INVREQ. Apr 25, 2014 · RESP (RESPONSE-CODE) RESP2 (RESPONSE-CODE2) NOHANDLE END-EXEC I am trying the Length, just to see if it fixes the issue. If the problem is caused by a CICS Automation logic problem, contact your IBM Support Center This command will return information in the first two words. You are using the MVS Coupling Facility May 9, 2011 · An EIBRESP of 16 in an INVREQ. Product Menu Topics. 2. The other three words will be set to nulls. EXCI response codes (returned in response field of return_area) Code Meaning Explanation; 0: OK: For all EXCI CALL commands other than the DPL_request, the call was successful. Notify the CICS administrator and systems programmer. This problem is caused by a transaction that altered storage in the CICS address space, or by a CICS Automation logic problem. Change your code to remove the STARTBR from the loop. 0. EIBRESP Response Codes. Feb 8, 2021 · EXEC CICS ABEND ABCODE (RESPONSE-CODE-X-5-8) END-EXEC END-IF. When you force the job to run on the same LPAR, it runs correctly. Any help is appreciated. Jun 15, 2018 · Symptom. This is similar to RSN=0024. Solution - LINK with INPUTMSG should not be coded in the program invoked by DPL. Task is abnormally terminated. the abend code is returned to the The primary response code indicating whether the external CICS interface LINK command caused an exception condition during its execution. A CICS call (DFHEDAP, EXEC CICS CSD, or CICS SPI) completed with a non-zero return code (see the RC= value) when processing a list of objects. Back to top. %PDF-1. Aug 23, 2012 · Re: EXCI reason codes for response 16. The response shows HTTP/1. If the client program is not written to handle the abend returned by the server program, the client program abends with the same abend code returned by the server program. Jun 27, 2019 · The external CICS interface (EXCI) provides a LINK command that performs all six commands of the interface in one invocation. If a server program abends, the abend code is returned to the client program. None. Any further information is in EIBRESP2 rather than EIBRCODE. System programmer response. Response codes of EXEC CICS commands. PDF. Each CICS command has its own set of possible exception conditions. The CICS region is running on a different LPAR from the batch job. RESP The primary response code, which indicates whether the external CICS interface GET CONTAINER command caused an exception condition during its execution. 101. Open/Close Topics Navigation. CICS might log in the MSGUSR output information/warning (RC=4) or exception messages (RC > 4) for this condition. You're probably in a loop in your CICS program, did a STARTBR already that worked, and now your loop is trying to do another STARTBR, giving your the RESP=16, RESP2=33. An OPEN_Pipe fails with RC=16, Reason Code=609 ( RC16 RSN609 ). Table 1. 19 - A LINK command with the INPUTMSG option is issued for a program that is the subject of a DPL request. RESP and RESP2 options. RESP2 The secondary response code that further qualifies, where necessary, some of the conditions raised in the RESP parameter. The format of the 5-word return area for the EXCI CALL interface is as follows: SYSVIEW® Performance Management 16. An Abend code is displayed that identifies the exceptional condition You receive Resp 16 and Resp2 107 when using the CICS Transaction Server for z/OS (CICS TS) application programming interface (API) command EXEC CICS INVOKE WEBSERVICE. * CICS sent this message: DFHAC2206 16:58:50 CICSTS54 Transaction I000 failed with abend 0012. Determine the cause of the problem. Solution - Debug the program why the transaction id having all blanks and correct it. If an OK response is received for a DPL_request, you must also check dpl_retarea to Jul 11, 2011 · EXEC CICS STARTBR DATASET (WS-BKP-FILE) RIDFLD (WS-BKP) RESP (WS-RESP-CODE) GTEQ END-EXEC the above startbr command execution is successful with 0000 response code then readnext,once sequential read is done, im issuing below endbr command EXEC CICS ENDBR DATASET(WS-BKP-FILE) Jun 27, 2019 · Description. What your code calls EXCI-RETURN-CODE is supposed to be defined as (from the External Interfaces Guide manual): 3. 2 The code page specified on the INTOCODEPAGE option and the code page of the channel are an unsupported combination. An attempt is made to start a browse with a REQID already in use for another browse. Use the response codes to help in problem determination. It is strongly recommended to check possible exception conditions after every CICS command. to EXEC CICS Aug 23, 2012 · EXCI reason codes for response 16. I am running. 2 %âãÏÓ 2639 0 obj /Linearized 1 /O 2641 /H [ 974 4016 ] /L 1354315 /E 27129 /N 503 /T 1301415 >> endobj xref 2639 28 0000000016 00000 n 0000000915 00000 n 0000004990 00000 n 0000005169 00000 n 0000005350 00000 n 0000005658 00000 n 0000007937 00000 n 0000008940 00000 n 0000009050 00000 n 0000010835 00000 n 0000012620 00000 n 0000013041 00000 n 0000014077 00000 n 0000014366 00000 n After the execution of an EXEC CICS command, fields EIBRESP and EIBRCODE are set to indicate whether the command executed successfully, or whether a CICS® condition was raised. You cannot use DPL to link to the CICS main terminal program, DFHEMTA, or to the RDO program The code page specified on the INTOCODEPAGE option is not supported. Modify the application program to correct it. The data was returned without any code page conversion. 0 16. When this command is used to write a record to a CICS®-maintained data table, the update is made to both the source VSAM KSDS and the in-memory data table, unless the XDTAD user exit rejects the record from the table. 4 CICS - Status Codes - While working with CICS, you may encounter abends. The web page explains the RESP option, the DFHRESP function, and the error codes with examples. After the execution of an EXEC CICS command, fields EIBRESP and EIBRCODE are set to indicate whether the command executed successfully, or whether a CICS condition was raised. Code page conversion is not possible. by Robert Sample » Thu Aug 23, 2012 1:01 pm. tbzejir zirxndt oncgj ncmns ytg rzwgb eeggr mliisb hmekw xquvmu